The CloudEngine S6730-H-V2 series offers a range of next generation 10 GE routing switches with 24, 28, or 48 downlink ports plus 6 x 40 GE uplink ports — which can be expanded to 100 GE through licensing — and one extended slot.
Built on Huawei's unified software platform , the series offers a range of various Intent-Driven Network (IDN) features, including support for Virtual Extensible Local Area Network (VXLAN) technology, which builds one network for multiple purposes. Meanwhile, a free mobility feature ensures a consistent user experience.
The S6730-H28X6CZ-V2 is a next-generation enterprise-class core and aggregation switch designed to meet the evolving demands of modern networks. Part of Huawei's CloudEngine S6730-H-V2 series, this switch offers high performance, flexibility, and advanced features suitable for various networking scenarios.
The S6730-H28X6CZ-V2 boasts several notable features:
▪ High puerto Density: Equipped with 28 x 10 GE SFP+ downlink ports and 6 x 40/100 GE QSFP28 uplink ports, providing ample connectivity options.
▪ Flexible Uplink Los puertos: Default 40 Gbit/s uplink ports can be upgraded to 100 GE through licensing, allowing for scalable network growth.
▪ Advanced VXLAN Support: Supports Virtual Extensible LAN (VXLAN) for network virtualization, enabling the creation of multiple virtual networks over a physical infrastructure.
▪ High Switching Capacity: fueraers a switching capacity of up to 2.4 Tbps, ensuring efficient data forwarding and minimal latency.
▪ rojoundant Power Supply: Features dual pluggable power modules with 1+1 redundancy, enhancing system reliability.
▪ Intelligent Stack (iStack): Supports iStack technology, allowing multiple switches to function as a single logical device for simplified management and enhanced scalability.
▪ Comprehensive Security Features: Includes various security mechanisms such as 802.1X authentication, MAC address filtering, and port security to safeguard network integrity.
▪ Energy Efficiency: Designed with energy-saving features to reduce power consumption without compromising performance.
▪ Robust Calidad de servicio (QoS): Provides advanced QoS capabilities to prioritize critical traffic and ensure optimal performance for essential applications.
▪ Enhanced O&M: fueraers intelligent operations and maintenance features, including real-time monitoring and diagnostics, to simplify network management.
Below are the key technical specifications of the S6730-H28X6CZ-V2:Fixed Ports:28 x 10 GE SFP+
Uplink Ports:6 x 40/100 GE QSFP28
Extended Slots:1 extended slot
Switching Capacity:1.76 Tbps / 2.4 Tbps
Forwarding Performance:490 Mpps
Power Supply:Dual pluggable power modules, 1+1 redundancy
Dimensions (W x D x H):442 mm x 420 mm x 43.6 mm
Weight:7.06 kg
The S6730-H28X6CZ-V2 is versatile and can be deployed in various scenarios:
▪ Enterprise Campus Networks: Serves as a core or aggregation switch, providing high-speed connectivity and advanced features to support large-scale enterprise environments.
▪ Data Centers: Functions as a top-of-rack (ToR) or end-of-row (EoR) switch, offering high-density 10 GE ports and flexible uplink options for efficient data center networking.
▪ Service Provider Networks: Suitable for aggregation and core layers, delivering robust performance and scalability to meet the demands of service provider infrastructures.
The S6730-H28X6CZ-V2 is equipped with advanced networking features to enhance performance and flexibility:
The switch supports VXLAN L2 and L3 gateways, enabling the creation of virtualized networks over a shared physical infrastructure. This capability allows for the segmentation of network resources and supports multi-tenant environments.
With iStack technology, multiple S6730-H28X6CZ-V2 switches can be interconnected to form a single logical device. This simplifies network management and enhances scalability, allowing for seamless network expansion.
The switch offers robust security features, including:▪ 802.1X Authentication: Ensures that only authorized devices can access the network.
▪ MAC Address Filtering: Allows for the control of device access based on MAC addresses.
▪ Port Security: Protects against unauthorized access by limiting the number of valid MAC addresses allowed on a port.
The S6730-H28X6CZ-V2 simplifies network management and maintenance through:
▪ Cloud Management: Supports cloud-managed network services throughout the full lifecycle, from planning and deployment to monitoring and optimization.
▪ Intelligent O&M: Provides real-time monitoring, diagnostics, and analytics to proactively identify and resolve network issues.
▪ Unified User Management: Authenticates both wired and wireless users, ensuring a consistent experience across the network.
Designed with energy efficiency in mind, the S6730-H28X6CZ-V2 incorporates:
▪ Energy-Efficient Ethernet (EEE): Reduces power consumption during periods of low network activity.
▪ Intelligent Fan Control: Adjusts fan speed based on system temperature to minimize energy usage.
▪ Low-Power Componentes componentes: Utilizes high-efficiency power supplies and components to decrease overall energy consumption.
The S6730-H28X6CZ-V2 provides advanced QoS features to ensure optimal performance for critical applications. It supports traffic classification, queue scheduling, and congestion control to prioritize essential data.
With flexible bandwidth management, network administrators can allocate resources efficiently, ensuring high-priority applications receive the necessary bandwidth while preventing congestion.
The switch minimizes delay with its high-performance forwarding architecture, making it suitable for latency-sensitive applications such as VoIP and video conferencing.
The S6730-H28X6CZ-V2 ensures network reliability with built-in redundancy and failover mechanisms:
▪ 1+1 Redundant Power Supply: Supports hot-swappable power modules for uninterrupted operation.
▪ Intelligent Link Backup: Automatically reroutes traffic in case of link failure to maintain connectivity.
▪ Loop Prevention Mechanisms: Supports STP, RSTP, and El MSTP to prevent network loops.
This switch is ideal for a variety of network environments:
▪ Large Enterprises: Provides high-speed connectivity and security for large corporate networks.
▪ Service Providers: Acts as an aggregation or core switch in ISP and carrier networks.
▪ Government and Education: Supports secure and scalable networking solutions for institutions.
The Huawei S6730-H28X6CZ-V2 is a powerful, flexible, and feature-rich switch designed for modern networking needs. Its high-performance switching capacity, advanced security features, and energy-efficient design make it an excellent choice for enterprises, data centers, and service providers looking for a scalable and reliable solution.
Huawei CloudEngine S6730-H Switches
Huawei All Series Switches New and Used
For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com (Email: [email protected] (en inglés))
Table 4-27 Basic information about the S6730-H28X6CZ-V2
El artículo | detalles |
---|---|
descripción | S6730-H28X6CZ-V2 bundle (28*10GE SFP+ ports, 6*100GE QSFP28 ports, with license, 1*expansion slot, without power module) |
Número de pieza | 02354VCR |
modelo | S6730-H28X6CZ-V2 |
Primera versión compatible | V600R022C00 |
observaciones | By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. |
Figure 4-10 S6730-H28X6CZ-V2 appearance
1 | Twenty-eight 10GE SFP+ optical ports | 2 | Seis puertos ópticos 40GE/100GE QSFP28 Nota:By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. |
3 | Un botón de un PNP NOTICE:To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 4 | Tornillo de tierra Nota:It is used with a ground cable. |
5 | Card slot Nota:In versions earlier than V600R024C00, this card slot is reserved. Applicable card: HSIC-X08S000 (available since V600R024C00 version) | 6 | Un puerto USB |
7 | Una ti ti gestión puerto | 8 | Un puerto de consola |
9 | 1 Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 10 | Ranura 2 para el módulo del ventilador Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 | 3 Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 12 | 1 Nota:Applicable power modules:
|
13 | Ranura para módulo de potencia 2 Nota:Applicable power modules:
| - | - |
Table 4-28 Ports on the S6730-H28X6CZ-V2
Port | Tipo de conector | descripción | Available Components |
---|---|---|---|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
40GE/100GE QSFP28 optical port | QSFP28 | By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. In V600R023C10 and later versions, the last two 100GE ports can each be split into four 25GE ports using a command. The port can be automatically converted into four 10GE ports using one-to-four QSFP+ optical modules or AOC optical cables. |
|
Puerto de consola | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
Gestión del puerto | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | Ethernet cable |
Puerto USB | USB 2.0 Type A | The USB port can have a Unidad flash USB connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. | USB flash drive |
Figure 4-11 Indicators on the switchTable 4-29 descripción of indicators on the switch
No. | Indicator | nombre | Color Color Color Color | Estado de la situación | descripción |
---|---|---|---|---|---|
1 | SYS | Indicador de estado del sistema | - | fuera | El sistema no está funcionando. |
verde | Parpadeo rápido | El sistema está arrancando. | |||
verde | Firme sobre | Durante la fase de preparación de la puesta en marcha del sistema, el indicador SYS es de color verde constante, que dura un máximo de 30 segundos. | |||
verde | Parintermitente lento | El sistema está funcionando normalmente. | |||
Red | Firme sobre | A fault that affects services has occurred and it cannot be rectified automatically (critical alarm about hardware). | |||
2 | MST | Indicador de pila | - | fuera | El interruptor no es el interruptor maestro en una pila. |
verde | parintermitente | El interruptor es el interruptor maestro en una pila o un interruptor independiente. | |||
3 | ID | Indicador de identificación | - | fuera | El indicador ID no se utiliza (estado por defecto). |
Azul azul | Firme sobre | El indicador identifica el interruptor a mantener. El indicador de identificación puede ser encendido o apagado remotamente para ayudar a los ingenieros de campo a encontrar el interruptor a mantener. | |||
4 | - | Indicador del puerto de servicio (dos indicadores para cada puerto) Nota:Cada puerto óptico tiene dos indicadores de un solo color. El de la izquierda es el indicador ACT (amarillo), yel de la derecha es el indicador LINK (verde). Las puntas de flecha muestran las posiciones de los puertos. Una punta de flecha hacia abajo indica un puerto en la parte inferior, y una punta de flecha hacia arriba indica un puerto en la parte superior. | Meanings of service port indicators vary in different modes. For details, see Table 4-30 and Table 4-31. | ||
5 | - | Indicador del puerto de servicio (un indicador para cada puerto) Nota:Each optical port has one single-color indicator. Arrowheads show the positions of ports. | |||
6 | L/A | El indicador del puerto | - | fuera | El puerto ETH no está conectado. |
verde | Firme sobre | El puerto ETH está conectado. | |||
verde | parintermitente | El puerto Eth está enviando o recibiendo datos. |
Table 4-30 descripción of service port indicators in different modes (two indicators for each port)
Display Mode | Color | Estado de la situación | Description |
---|---|---|---|
Default mode (LINK indicator) | verde | fuera | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | Se ha establecido un enlace en el puerto. | |
Default mode (ACT indicator) | amarillo | fuera | El puerto no está enviando o recibiendo datos. |
amarillo | parintermitente | El puerto está enviando o recibiendo datos. | |
Speed mode (LINK indicator) Nota:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | fuera | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | 1GE/10GE SFP+ port: The port is operating at 1 Gbit/s. | |
verde | parintermitente | 1GE/10GE SFP+ port: The port is operating at 10 Gbit/s. |
Table 4-31 Description of service port indicators in different modes (one indicator for each port)
Display Mode | Color | Estado de la situación | Description |
---|---|---|---|
Default mode | - | Off | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | Se ha establecido un enlace en el puerto. | |
verde | parintermitente | El puerto está enviando o recibiendo datos. | |
Speed mode Nota:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | Off | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | 40GE/100GE QSFP28 port: The port is operating at 40 Gbit/s. | |
verde | parintermitente | 40GE/100GE QSFP28 port: The port is operating at 100 Gbit/s. |
The switch can use a single power module or two power modules for 1+1 power redundancy. Los módulos de alimentación de ca y DC enchupables se pueden utilizar juntos en el mismo interruptor.
The switch uses pluggable fan modules for forced air cooling. Air flows in from the right and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Table 4-32 Technical specifications of the S6730-H28X6CZ-V2
El artículo | especificación |
---|---|
Dimensiones sin embalaje (H x W x D) [mm(in.)] | Dimensiones básicas (excluyendo las partes que sobresalen del cuerpo): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. X 17.4 in. X 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 455.0 mm (1.72 in. x 17.4 in. x 17.91 in.) |
Dimensiones con embalaje (H x W x D) [mm(in.)] | 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Altura del chasis [U] | 1 |
Chassis material | Metal |
Peso sin embalaje [kg(lb)] | 7.06 kg (15.56 lb) |
Peso con embalaje [kg(lb)] | 10.04 kg (22.13 lb) |
Consumo típico de energía [W] | 203 W |
Disipación típica de calor [BTU/ hora] | 692.66 BTU/hour |
Consumo máximo de energía [W] | 263 W |
Máxima disipación de calor [BTU/ hora] | 897.38 BTU/hour |
Consumo de energía estática [W] | 136 W |
MTBF [años] | 52.24 years |
MTTR [horas] | 2 horas |
disponibilidad | > 0.99999 |
Ruido A temperatura normal (potencia acústica) [dB(A)] | 53.4 dB(A) |
Ruido A temperatura normal (presión acústica) [dB(A)] | 39.72 dB(A) |
Número de ranuras de tarjetas | 1 |
Número de ranuras de corriente | 2 |
Número de módulos de ventil | 3 |
Fuente de alimentación redund | 1+1 Posibilidad de conexión AC and DC power modules can be used together in the same switch. |
Temperatura de funcionamiento a largo plazo [°C(°F)] | -5 °C a +45°C (23°F a 113°F) a una altitud de 0 a 1800 m (0 a 5905,44 pies). |
Restricción de la tasa de variación de la temperatura de funcionamiento [− C(− F)] | Cuando la altitud es de 1800-5000 m (5906-16404 pies), la temperatura de operación más alta se reduce en 1°C (1,8 °F) cada vez que la altitud aumenta en 220 m (722 pies). Los dispositivos no pueden arrancar cuando la temperatura es inferior a 0°C (32°F). Cuando se utiliza el módulo óptico QSFP-100G-ER4, la temperatura de operación varía de -5°C a +40°C (23°F a 104°F). |
Temperatura de almacenamiento [°C(°F)] | -40 °C a +70°C (-40 °F a +158°F) |
Humedad relativa operativa a largo plazo [hr] | 5% de RH a 95% de RH (sin condensación) |
Altitud operativa a largo plazo [m(ft.)] | 0-5000 m (0-16404 pies) |
Altitud de almacenamiento [m(ft.)] | 0-5000 m (0-16404 pies) |
Modo de alimentación | Fuente de alimentación enchufable |
Tensión nominal de entrada [V] |
|
Rango de tensión de entrada [V] |
|
Corriente máxima de entrada [A] | Las especificaciones actuales están relacionadas con el módulo de alimentación enchufable. Para más detalles, consulte módulos de alimentación enchufables. |
memoria | 4 GB |
Memoria Flash | Physical space: 2 GB |
Puerto de consola | RJ45 |
Gestión del puerto | RJ45 |
USB | apoyado |
RTC | apoyado |
Entrada RPS | No soport |
Protección contra aumentos de tensión en los puertos de servicio [kV] | - |
Protección contra aumento de tensión de la fuente de alimentación [kV] |
|
Nivel de protección contra la entrada (resistente al polvo/al agua) | IP20 |
Tipos de ventiladores | Pluggable |
Modo de disipación del calor | Refrigeración por aire para disipación de calor, ajuste inteligente de la velocidad del ventilador |
Dirección del flujo de aire | Air intake from front and right and air exhaust from rear |
PoE | No soport |
certificación | Certificación EMC Certificación de seguridad Certificación de fabricación |