Introduction to Huawei CloudEngine S5731-S24P4X

The Huawei CloudEngine S5731-S24P4X is a high-performance, next-generation gigabit access switch designed to meet the demands of modern enterprise networks. Built on Huawei's Versatile Routing Platform (VRP), this switch offers enhanced Layer 3 features, simplified operations and maintenance (O&M), intelligent stacking (iStack), flexible Ethernet networking, and mature IPv6 capabilities.


Key Features

▪ High-Performance Hardware: Equipped with 24 x 10/100/1000BASE-T PoE+ ports and 4 x 10GE SFP+ uplink ports, ensuring robust connectivity.
▪ Advanced Layer 3 Capabilities: Supports comprehensive Layer 3 routing protocols, including OSPF, IS-IS, BGP, and VRRP.
▪ Intelligent Stacking (iStack): Allows multiple switches to be managed as a single entity, simplifying network management.
▪ Enhanced Security Features: Offers features like MAC address authentication, 802.1X, and port security to safeguard the network.
▪ Flexible Power Options: Supports various power modules, including 600W and 1000W PoE AC power supplies.

Especificaciones técnicas

Ports: 24 x 10/100/1000BASE-T PoE+ ports, 4 x 10GE SFP+ uplink ports
Switching Capacity: 128 Gbps
Forwarding Performance: 96 Mpps
Memory: 2 GB RAM, 1 GB Flash
Power Supply: Supports 600W and 1000W PoE AC power modules
Dimensions: 43.6 mm x 442 mm x 420 mm
Weight: Approximately 8.6 kg
Operating Temperature: 0°C to 50°C
Humidity: 5% to 95% (non-condensing)

Deployment Scenarios

The S5731-S24P4X is ideal for various deployment scenarios, including: 

▪ Enterprise Campus Networks: Serves as an access switch, providing high-speed connectivity to end devices.
▪ Aggregation Layer: Functions as an aggregation switch, consolidating traffic from multiple access switches.
▪ Data Center Access: Connects servers and storage devices within data centers, ensuring low-latency communication.

Seguridad y gestión

▪ Comprehensive Security: Implements features like DHCP snooping, dynamic ARP inspection, and IP source guard to prevent unauthorized access.
▪ Efficient Management: Supports SNMP, RMON, Syslog, and NTP for streamlined network management.
▪ Web-Based GUI: Offers an intuitive web interface for easy configuration and monitoring.

Energy Efficiency

The S5731-S24P4X is designed with energy efficiency in mind: 

▪ Dynamic Energy Saving: Automatically adjusts power consumption based on network traffic.
▪ Fan Speed Adjustment: Modulates fan speed according to system temperature, reducing noise and power usage.
▪ PoE Management: Provides intelligent PoE management, delivering power only when needed.

conclusión

The Huawei CloudEngine S5731-S24P4X stands out as a versatile and high-performance switch, suitable for various network environments. Its robust feature set, combined with energy-efficient design and comprehensive security measures, makes it an excellent choice for enterprises seeking reliable and scalable network solutions.


Huawei CloudEngine Switch S5731-S24P4X (02353AHX/-001/-003/-004)

Huawei All serie Switches New and Used

For Huawei product list and quote, please visit: https://www.hi-network.com/categories/huawei or contact us at www.hi-network.com  (Email: [email protected] (en inglés))



S5731-S24P4X (02353AHX/02353AHX-001/02353AHX-003)

Version Mapping

Table 4-1316 lists the mapping between the S5731-S24P4X chassis and software versions.

Table 4-1316 Version mapping

Series

modelo

Versión del Software

S5731-S

S5731-S24P4X

02353AHX: V200R019C00 and later versions

02353AHX-001: V200R020C10 and later versions

02353AHX-003: V200R021C10SPC600 and later versions (If V200R021C10SPC500 is used, install V200R021HP0121 or a later patch.)

Appearance and Structure

Figure 4-520 S5731-S24P4X (02353AHX) appearance
Figure 4-521 S5731-S24P4X (02353AHX-001/02353AHX-003) appearance

1

24 puertos PoE+ 10/100/1000BASE-T

2

Cuatro puertos 10GE SFP+

Módulos y cables aplicables:
  • Módulo óptico GE

  • Módulo óptico GE-CWDM

  • Módulo óptico GE-DWDM

  • GE copper module (100M/1000M auto-sensing)

  • Módulo óptico 10GE SFP+ (no compatible con OSXD22N00)

  • 10GE-CWDM optical module (en inglés)

  • 10GE-DWDM optical module (en inglés)

  • PEN remote optical modules (V200R024C00 and later versions)

  • 1 m, 3 m, 5 m y 10 m SFP+ cables de cobre de alta velocidad

  • Cables de 3 m y 10 m SFP+ AOC

  • 0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking)

3

Un puerto de consola

4

Una ti ti gestión puerto

5

Un puerto USB

6

Un botón de un PNP

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

7

Tornillo de tierra

Nota:
It is used with a ground cable.

8

1

Nota:

Applicable fan module: FAN-023A-B (Fan Box (B, Fan Panel Side Exhaust))

9

Ranura 2 para el módulo del ventilador

Nota:

Applicable fan module: FAN-023A-B (Fan Box (B, Fan Panel Side Exhaust))

10

1

Nota:

Applicable power module:

  • PAC1000S56-CB (02312KND: 1000 W PoE AC&240 V DC Power Module)

  • PAC1000S56-CB (02312KND-001: 1000 W PoE AC&240 V DC Power Module) (applicable in V200R019C10 and later versions)

  • PAC1000S56-DB (1000 W PoE AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S56-CB (1000 W PoE DC Power Module) (applicable in V200R021C00 and later versions)

  • PAC600S56-CB (600 W PoE AC&240 V DC Power Module (Back to Front, Power panel side exhaust)) (applicable in V200R021C10 and later versions)

11

Ranura para módulo de potencia 2

Nota:

Applicable power module:

  • PAC1000S56-CB (02312KND: 1000 W PoE AC&240 V DC Power Module)

  • PAC1000S56-CB (02312KND-001: 1000 W PoE AC&240 V DC Power Module) (applicable in V200R019C10 and later versions)

  • PAC1000S56-DB (1000 W PoE AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S56-CB (1000 W PoE DC Power Module) (applicable in V200R021C00 and later versions)

  • PAC600S56-CB (600 W PoE AC&240 V DC Power Module (Back to Front, Power panel side exhaust)) (applicable in V200R021C10 and later versions)

-

-

Port descripción

Puerto 10/100/1000BASE-T

A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s, and must use an Ethernet cable. Table 4-1317 describes the attributes of a 10/100/1000BASE-T Ethernet electrical port.
Table 4-1317 Attributes of a 10/100/1000BASE-T Ethernet electrical port

Attribute

descripción

Tipo de conector

RJ45

Standards compliance

IEEE802.3, IEEE802.3u, IEEE802.3ab

Modo de trabajo

10/100/1000 Mbit/s auto-sensing

Maximum transmission distance

100 m

10GE SFP+ optical port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-1318 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-1318 Attributes of a 10GE SFP+ port

Attribute

descripción

Tipo de conector

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Modo de trabajo

GE/10GE auto-sensing

Puerto de consola

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-1319.
Table 4-1319 Attributes of a console port

Attribute

descripción

Tipo de conector

RJ45

Standards compliance

RS-232

Modo de trabajo

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Gestión del puerto

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-1320 describes the attributes of an ETH management port.
Table 4-1320 Attributes of an ETH management port

Attribute

descripción

Tipo de conector

RJ45

Standards compliance

IEEE802.3

Working Mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 m

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration. If you have logged in to the switch for the first time by pressing and holding the MODE button for 6 seconds or longer and saved the configuration, the default configuration on the ETH port will be cleared. In this case, you cannot log in to the switch for the first time through the ETH port. You are advised to log in to the switch for the first time through the ETH port.

Puerto USB

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicator Description

The S5731-S24P4X has the same types of indicators as the S5731-S48P4X. For details, see Indicator Description.

Power Supply Configuration

The switch is a PoE switch and supports two power module slots, each of which can have a 1000 W PoE or 600 W PoE power module installed. Pluggable AC and DC PoE power modules can be used together in the same switch.

Table 4-1321 Power supply configurations

Power Module 1

Power Module 2

Alimentación PoE disponible

Maximum Number of Ports (Fully Loaded)

1000 W AC (220 V)

1000 W DC

-

760 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 24

1000 W AC (110 V)

-

665 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 22

1000 W AC (220 V)

1000 W DC

1000 W AC (220 V)

1000 W DC

1600 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 24

1000 W AC (110 V)

1000 W DC

1000 W AC (110 V)

Versions earlier than V200R021C10: 1330 W

V200R021C10 and later versions: 1520 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 24

600 W AC (220 V)

-

380 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 12

600 W AC (110 V)

-

95 W

  • 802.3af (15.4 W per port): 6

  • 802.3at (30 W per port): 3

600 W AC (220 V)

600 W AC (220 V)

950 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 24

600 W AC (110 V)

600 W AC (110 V)

380 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 12

1000 W AC (220 V)

1000 W DC

600 W AC (220 V)

1330 W

  • 802.3af (15.4 W per port): 24

  • 802.3at (30 W per port): 24

When a switch has two power modules installed, the two power modules work in redundancy mode to provide power for the chassis and in load balancing mode to provide power for PDs.

Disipación de calor

The S5731-S24P4X uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

Especificaciones técnicas

Table 4-1322 lists technical specifications of the S5731-S24P4X.

Table 4-1322 Technical specifications

El artículo

Description

Memoria (RAM)

2 GB

Flash

1 GB en total. Para ver el tamaño de la memoria flash disponible, ejecute the Versión de visualizaciónRe88pl99ace1command.

Tiempo medio entre fallas (MTBF)

57 años

disponibilidad

> 0.99999

Protección de puertos de servicio

Modo común: − 6 kV

Protección contra aumento de tensión de la fuente de alimentación

  • Usando módulos de alimentación de ca: − 6 kV en modo diferencial, − 6 kV en modo común

  • Usando módulos de alimentación DC: − 2 kV en modo diferencial, − 4 kV en modo común

Dimensiones (H x W x D)

  • Dimensiones básicas (excluyendo las partes que sobresalen del cuerpo): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. X 17.4 in. X 16.5 in.)

  • Dimensiones máximas (la profundidad es la distancia desde los puertos en el panel delantero a la manija en el panel trasero): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. X 17.4 in. X 17.7 in.)

Peso (con embalaje)

8.6 kg (18.96 lb)

Puertos de pila

Puertos 10GE SFP+ en el panel frontal

RTC

apoyado

RPS

No soport

PoE

apoyado

Rango de tensión nominal

  • Entrada de ca: 100 V de AC a 130 V de AC, 200 V de AC a 240 V de AC, 50/60 Hz

  • Entrada DC de alta tensión: 240 V DC

  • Entrada DC: -48 V DC to -60 V DC

Rango de tensión máxima

  • Entrada de ca: 90 V de ca a 290 V de ca, 45 Hz a 65 Hz

  • Entrada DC de alta tensión: 190 V DC a 290 V DC

  • Entrada DC: -38.4 V DC to -72 V DC

Consumo máximo de energía (100% de rendimiento, velocidad máxima de los ventiladores)

  • No proporcionar la función PoE: 121 W

  • Cargas 100% PoE: 977 W (PoE: 720 W)

Consumo típico de energía (30% de la carga de tráfico, probado según la norma ATIS)

95 W

Temperatura de funcionamiento

-5°C a +45°C (23°F a 113°F) a una altitud de 0-1800 m (0-5906 pies).
Nota:

Cuando la altitud es de 1800-5000 m (5906-16404 pies), la temperatura de operación más alta se reduce en 1°C (1,8 °F) cada vez que la altitud aumenta en 220 m (722 pies).

El interruptor no se puede iniciar cuando la temperatura ambiente es inferior a 0°C (32°F).

Temperatura de almacenamiento

-40°C a +70°C (-40°F a +158°F)

Ruido a temperatura normal (27°C, potencia acústica)

< 62,3 dB(A)

Humedad relativa

5% a 95%, sin condensación

Altitud de operación

0-5000 m (0-16404 pies)

certificación

  • Certificación EMC

  • Certificación de seguridad

  • Certificación de fabricación

Número de pieza

02353AHX

02353AHX-001

02353AHX-003


tag-icon Etiquetas calientes: Huawei Switches hot products

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.