Regístrese ahora para una mejor cotización personalizada!

Noticias calientes

Huawei S6730-S24X6Q: Advanced Ethernet Switch for Modern Networks

Jan, 23, 2025 Hi-network.com

s6730-s24x6q

The Huawei | S6730-S24X6Q is a high-performance Ethernet interruptor designed to meet the demands of modern data centers and campus networks. It offers advanced features and robust specifications to ensure efficient and reliable network operations.

Key Features

▪ High Port Density: 24 x 10 Gigabit SFP+ ports and 6 x 40 Gigabit QSFP+ ports.
▪ High Switching Capacity: Up to 2.4 Tbit/s to handle heavy traffic loads.
▪ Advanced Layer 2 and Layer 3 Features: Supports comprehensive protocols for versatile network configurations.
▪ Stacking Capability: Supports stacking through 10GE SFP+ and 40GE QSFP+ ports for simplified management.
▪ Energy Efficiency: Designed for low power consumption to reduce operational costs.
▪ Comprehensive Security: fueraers features like ACLs, 802.1X authentication, and DHCP snooping for enhanced network protection.
▪ Calidad de servicio (QoS): Provides traffic classification and prioritization to ensure optimal performance for critical applications.
▪ Flexible Management: Supports various management methods, including CLI, web-based management, and SNMP.
▪ High Reliability: Features redundant power supplies and hot-swappable fan modules for continuous operation.
▪ Virtual Extensible LAN (VXLAN): Supports VXLAN L2 and L3 gateways for network virtualization.

Especificaciones técnicas

Ports: 24 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports.
Switching Capacity: 2.4 Tbit/s.
Forwarding Performance: 480 Mpps.
Dimensiones (H x W x D): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.).
Peso (con embalaje): 8.9 kg (19.62 lb).
Power Supply: Supports dual AC and DC power modules.
Operating Temperature: -5°C a +45°C (23°F a 113°F) a una altitud de 0-1800 m (0-5906 pies)..
Operating Humidity: 5% a 95%, sin condensación.
Stacking Support: Up to 16 physical ports for stacking using 10GE SFP+ and 40GE QSFP+ ports.
Airflow Direction: Air intake from front, air exhaustion from rear (front-to-rear).

Port Details

10GE SFP+ Ports: 24 ports supporting various optical modules and cables, including Módulo óptico GEs, 10GE SFP+ optical modules, and high-speed copper cables.
40GE QSFP+ Ports: 6 ports compatible with Módulo óptico QSFP+s and high-speed copper cables. Note: A QSFP+ optical port cannot be split into four 10GE ports.

Potencia y refrigeración

The S6730-S24X6Q supports dual hot-swappable power modules, allowing for AC and DC inputs:
AC Input: 100 V AC to 240 V AC, 50/60 Hz.
High-Voltage DC Input: 240 V DC.
DC Input: -48 V DC to -60 V DC.
Maximum Power Consumption: 249 W.
Typical Power Consumption: 135 W.
Fan Modules: Four pluggable fan modules with front-to-rear airflow design for efficient cooling.

Stacking and Virtualization

The switch supports stacking through its 10GE SFP+ and 40GE QSFP+ ports, allowing multiple switches to function as a single logical unit for simplified management and enhanced scalability. It also supports VXLAN L2 and L3 gateways, enabling network virtualization for flexible and efficient network designs.


Elementos de seguridad

The S6730-S24X6Q offers comprehensive security features to protect network integrity:
Access Control Lists (ACLs): Permit or deny traffic based on predefined security policies.
802.1X Authentication: Ensures that only authorized users can access the network.
DHCP Snooping: Prevents unauthorized DHCP servers from distributing IP addresses.
IP Source Guard: Blocks packets with spoofed IP addresses.
Dynamic ARP Inspection (DAI): Protects against ARP spoofing attacks.

Quality of Service (QoS)

The switch provides advanced QoS features to ensure optimal performance for critical applications:
Traffic Classification: Identifies and classifies incoming traffic based on various parameters.
Traffic Policing and Shaping: Controls the rate of traffic sent or received on a network interface.
Priority Queuing: Ensures that high-priority traffic is transmitted first.
Congestion Management: Implements mechanisms to prevent and manage network congestion.

Gestión y mantenimiento

The S6730-S24X6Q supports various management methods for ease of use:
Command-Line Interface (CLI): Provides a text-based interface for configuration and monitoring.
Web-Based Management: fueraers a graphical user interface accessible through web browsers.


Huawei CloudEngine S6730-S24X6Q Switches

Huawei All serie Switches New and Used

For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com  (Email: [email protected] (en inglés))



S6730-S24X6Q (02353AJW/02353AJW-001/02353AJW-003/02353AJW-004)

Version Mapping

Table 4-227 lists the mapping between the S6730-S24X6Q chassis and software versions.

Table 4-227 Version mapping

Series

modelo

Versión del Software

S6730-S

S6730-S24X6Q

02353AJW: V200R019C00 and later versions

02353AJW-001: V200R020C10 and later versions

02353AJW-003: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.)

02353AJW-004: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

Nota:

V200R021C01 is not supported.

Some models cannot be downgraded due to component upgrade. Therefore, you are advised to run the display system-software information command (supported in V200R021C00 and later versions) to check the software versions supported by the device before performing a downgrade.

Appearance and Structure

Figure 4-94 S6730-S24X6Q appearance

1

24 puertos 10GE SFP+

Módulos y cables aplicables:
  • GE optical module

  • Módulo óptico GE-CWDM

  • Módulo óptico GE-DWDM

  • «GE Copper module» (en inglés)

  • Módulo óptico 10GE SFP+ (no compatible con OSXD22N00)

  • 10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)

  • 10GE-CWDM optical module (en inglés)

  • 10GE-DWDM optical module (en inglés)

  • 1 m, 3 m, 5 m y 10 m SFP+ cables de cobre de alta velocidad

  • Cables de 3 m y 10 m SFP+ AOC

  • Cables de pila dedicados de 0,5 m y 1,5 m SFP+ (soportpor los últimos 16 puertos SFP+ y utilizado sólo para apilde configuración cero)

2

Seis puertos ópticos 40GE QSFP+

Módulos y cables aplicables:
  • QSFP+ optical module

  • 1 m, 3 m, y 5 m QSFP+ a QSFP+ cables de cobre de alta velocidad

  • 10 m QSFP+ a QSFP+ cable AOC

  • Cable de pila dedicado QSFP28 de 2 m (compatible con V200R020C10 y versiones posteriores)

  • QSFP28 optical module (supported in V200R024C00 and later versions, need a license loaded)

  • 1 m QSFP28 to QSFP28 high-speed copper cable (supported in V200R024C00 and later versions, need a license loaded)

  • 10 m QSFP28 to QSFP28 AOC cable (supported in V200R024C00 and later versions, need a license loaded)

Nota:

A QSFP+ optical port cannot be split into four 10GE ports.

In V200R024C00 and later versions, a RTU license can be loaded to increase the port rate to 100 Gbit/s.

The QSFP+ ports can work as 100GE ports after you activate the license, run the assign port-type 100ge [ La ranura slot-id | all ] command, and restart the switch.

3

Tornillo de tierra

Nota:
It is used with a ground cable.

4

Ranura para la tarjeta SSD

Nota:

This slot is reserved for future use.

5

Un puerto de consola

6

Una ti ti gestión puerto

7

Un puerto USB

8

Un botón de un PNP

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

9

1

Nota:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

10

Ranura 2 para el módulo del ventilador

Nota:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

11

3

Nota:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

12

Ranura 4 para el módulo del ventilador

Nota:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

13

1

Nota:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

14

Ranura para módulo de potencia 2

Nota:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

Port descripción

10GE SFP+ optical port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-228 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-228 Attributes of a 10GE SFP+ port

Attribute

descripción

Tipo de conector

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Modo de trabajo

GE/10GE auto-sensing

40GE QSFP+ optical port

A 40GE QSFP+ optical port sends and receives service traffic at 40 Gbit/s. Table 4-229 describes the attributes of a QSFP+ optical port.
Table 4-229 Attributes of a QSFP+ optical port

Attribute

descripción

Tipo de conector

MPO/LC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ba

Puerto de consola

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-230.
Table 4-230 Attributes of a console port

Attribute

descripción

Tipo de conector

RJ45

Standards compliance

RS-232

Modo de trabajo

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Gestión del puerto

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-231 describes the attributes of an ETH management port.
Table 4-231 Attributes of an ETH management port

Attribute

descripción

Tipo de conector

RJ45

Standards compliance

IEEE802.3

Working Mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 m

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration.

Puerto USB

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

indicador descripción

Figure 4-95 Indicators on the S6730-S24X6Q
Table 4-232 Description of indicators on the switch

No.

Indicator

nombre

Color Color

Estado de la situación

Description

1

SYS

Indicador de estado del sistema

-

fuera

El sistema no está funcionando.

verde

Parpadeo rápido

El sistema está arrancando.

verde

Firme sobre

Durante la fase de preparación de la puesta en marcha del sistema, el indicador SYS es de color verde constante, que dura un máximo de 30 segundos.

verde

Parintermitente lento

El sistema está funcionando normalmente.

rojo

Firme sobre

El sistema no funciona normalmente después del registro, o se ha generado una alarma de ventilador o una alarma de temperatura.

2

El MST

Indicador de pila

-

fuera

El interruptor no es el interruptor maestro en una pila.

verde

parintermitente

El interruptor es el interruptor maestro en una pila o un interruptor independiente.

3

ID

Indicador de identificación

-

fuera

El indicador ID no se utiliza (estado por defecto).

Azul azul

Firme sobre

El indicador identifica el interruptor a mantener. El indicador de identificación puede ser encendido o apagado remotamente para ayudar a los ingenieros de campo a encontrar el interruptor a mantener.

4

-

Service port indicator (10GE optical port)

Nota:

Cada puerto óptico tiene dos indicadores de un solo color. El de la izquierda es el indicador ACT (amarillo), yel de la derecha es el indicador LINK (verde).

Las puntas de flecha muestran las posiciones de los puertos. Una punta de flecha hacia abajo indica un puerto en la parte inferior, y una punta de flecha hacia arriba indica un puerto en la parte superior.

-

fuera

El puerto no está conectado o ha sido apagado.

verde

Firme sobre

Se ha establecido un enlace en el puerto.

-

fuera

El puerto no está enviando o recibiendo datos.

amarillo

parintermitente

El puerto está enviando o recibiendo datos.

5

-

Service port indicator (40GE optical port)

Nota:

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

-

fuera

El puerto no está conectado o ha sido apagado.

verde

Firme sobre

Se ha establecido un enlace en el puerto.

parintermitente

El puerto está enviando o recibiendo datos.

6

L/A

El indicador del puerto

-

Off

El puerto ETH no está conectado.

verde

Firme sobre

El puerto ETH está conectado.

verde

parintermitente

El puerto Eth está enviando o recibiendo datos.

7

USB

USB-based deployment indicator (en inglés)

-

Off

  • Ninguna unidad flash USB está conectada al interruptor.

  • El puerto USB está dañado.

  • El indicador está dañado.

  • La unidad flash USB no tiene ningún archivo de configuración y no se puede utilizar para el despliegue.

  • El interruptor se ha actualizado utilizando la unidad flash USB y se está reiniciando.

verde

Firme sobre

Un despliegue basado en USB se ha completado.

verde

parintermitente

El sistema está leyendo datos de una unidad flash del USB.

amarillo

Firme sobre

El conmutador ha copiado todos los archivos requeridos y completado la verificación de archivos. La unidad flash USB se puede quitar del interruptor.

rojo

parintermitente

Se ha producido un error cuando el sistema está ejecutando el archivo de configuración o leyendo datos desde la unidad flash USB.

Power Supply Configuration

The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Disipación de calor

The S6730-S24X6Q uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Especificaciones técnicas

Table 4-233 lists technical specifications of the S6730-S24X6Q.

Table 4-233 Technical specifications

El artículo

Description

Memoria (RAM)

4 GB

Flash

2 GB en total. Para ver el tamaño de la memoria flash disponible, ejecute the Versión de visualizaciónRe88pl99ace1command.

Tiempo medio entre fallas (MTBF)

62.27 años

Tiempo medio de reparación (MTTR)

2 horas

disponibilidad

> 0.99999

Protección de puertos de servicio

N/A

Protección contra aumento de tensión de la fuente de alimentación

  • Usando módulos de alimentación de ca: − 6 kV en modo diferencial, − 6 kV en modo común

  • Usando módulos de alimentación DC: − 2 kV en modo diferencial, − 4 kV en modo común

Dimensions (H x W x D)

  • Dimensiones básicas (excluyendo las partes que sobresalen del cuerpo): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. X 17.4 in. X 16.5 in.)

  • Dimensiones máximas (la profundidad es la distancia desde los puertos en el panel delantero a la manija en el panel trasero): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. X 17.4 in. X 17.6 in.)

Weight (with packaging)

8.9 kg (19.62 lb)

Puertos de pila

  • Cualquier puerto 10GE SFP+ (un máximo de 16 puertos físicos)

  • Cualquier puerto 40GE QSFP+ (un máximo de 6 puertos físicos)

RTC

apoyado

RPS

No soport

PoE

No soport

Rango de tensión nominal

  • Entrada de ca: 100 V de ca a 240 V de ca, 50/60 Hz

  • Entrada DC de alta tensión: 240 V DC

  • Entrada DC: -48 V DC to -60 V DC

Rango de tensión máxima

  • Entrada de ca: 90 V de ca a 290 V de ca, 45 Hz a 65 Hz

  • Entrada DC de alta tensión: 190 V DC a 290 V DC

  • Entrada DC: -38.4 V DC to -72 V DC

Consumo máximo de energía

High temperature 45°C (113°F), 100% traffic, and dual power modules: 170 W

High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 249 W

Consumo típico de energía

30% traffic under the ATIS standard and dual power modules: 135 W

Temperatura de funcionamiento

-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Nota:

Cuando la altitud es de 1800-5000 m (5906-16404 pies), la temperatura de operación más alta se reduce en 1°C (1,8 °F) cada vez que la altitud aumenta en 220 m (722 pies).

El interruptor no se puede iniciar cuando la temperatura ambiente es inferior a 0°C (32°F).

Temperatura de almacenamiento

-40°C a +70°C (-40°F a +158°F)

Ruido a temperatura normal (27°C, potencia acústica)

< 65 dB(A)

Humedad relativa

5% to 95%, noncondensing

Altitud de operación

0-5000 m (0-16404 pies)

certificación

  • Certificación EMC

  • Certificación de seguridad

  • Certificación de fabricación

Número de pieza

02353AJW

02353AJW-001

02353AJW-003

02353AJW-004


tag-icon Etiquetas calientes: Huawei Switches

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.