The S6730-H48X6C-V2 is a high-performance switch designed to meet the demands of modern data centers and enterprise networks. It offers advanced features and robust specifications to ensure reliable and efficient network operations.
▪ High puerto Density: Equipped with 48 × 10GE SFP+ ports and 6 × 40GE QSFP28 ports, providing extensive connectivity options.
▪ Flexible Uplink Options: Supports optional licenses for upgrading 40GE ports to 100GE QSFP28, allowing for scalable network growth.
▪ Advanced Cooling System: Utilizes pluggable fan modules for efficient forced air cooling, ensuring optimal performance under heavy workloads.
▪ rojoundant Power Supply: Features two power module slots supporting 1+1 redundancy with pluggable AC and DC power modules, enhancing reliability.
▪ Comprehensive Management Interfaces: Includes RJ45 console and management ports, along with USB support for versatile management options.
Dimensions: 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
Weight with Packaging: 9.2 kg (20.28 lb)
memoria: 4 GB
Flash Memory: Physical space: 2 GB
Typical Power Consumption: 165 W
Number of Power Slots: 2
Number of Fan Modules: 4
rojoundant Power Supply: 1+1 Posibilidad de conexión AC and DC power modules
Console Port: RJ45
Management Port: RJ45
USB Support: apoyado
The S6730-H48X6C-V2 is ideal for:
▪ Data Center Aggregation: Serving as a high-density aggregation switch in data center environments.
▪ Enterprise Core Layer: Functioning as a core switch in enterprise networks, providing high-speed connectivity and advanced features.
▪ Campus Network Aggregation: Acting as an aggregation switch in campus networks, supporting various services and applications.
The S6730-H48X6C-V2 switch offers a comprehensive solution for organizations seeking high-performance, scalable, and reliable network infrastructure. Its advanced features and robust specifications make it a suitable choice for various networking scenarios.
Huawei CloudEngine S6730-H48X6C Switches
Huawei All Series Switches New and Used
For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com (Email: [email protected] (en inglés))
Table 4-9 Basic information about the S6730-H48X6C-V2
El artículo | detalles |
---|---|
descripción | S6730-H48X6C-V2 (48*10GE SFP+ ports, 6*40GE QSFP28 ports, optional license for upgrade to 6*100GE QSFP28, without power module) |
Número de pieza | 02354HHT |
modelo | S6730-H48X6C-V2 |
Primera versión compatible | V600R022C00 |
observaciones | By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands. |
Figure 4-4 S6730-H48X6C-V2 appearance
1 | Cuarenta y ocho 10GE SFP+ ports | 2 | Seis puertos ópticos 40GE/100GE QSFP28 Nota:By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands. |
3 | Tornillo de tierra Nota:It is used with a ground cable. | 4 | Ranura para la tarjeta SSD Nota:This slot is reserved and cannot be used. |
5 | Un puerto de consola | 6 | Una ti ti gestión puerto |
7 | Un puerto USB | 8 | Un botón de un PNP NOTICE:To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
9 | 1 Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 10 | Ranura 2 para el módulo del ventilador Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 | 3 Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 12 | Ranura 4 para el módulo del ventilador Nota:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
13 | 1 Nota:Applicable power modules:
| 14 | Ranura para módulo de potencia 2 Nota:Applicable power modules:
|
Table 4-10 Ports on the S6730-H48X6C-V2
Port | Tipo de conector | descripción | Available Components |
---|---|---|---|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
40GE/100GE QSFP28 optical port | QSFP28 | By default, QSFP28 optical ports work at 40 Gbit/s. A 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s. To configure the ports to work at 100 Gbit/s, run the license active command to activate the license, and then run the active port-license and port mode 100GE interface commands. QSFP28 optical ports cannot be split. |
|
Puerto de consola | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
Gestión del puerto | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | Ethernet cable |
Puerto USB | USB 2.0 Type A | The USB port can have a Unidad flash USB connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. | USB flash drive |
Figure 4-5 Indicators on the switch
Table 4-11 descripción of indicators on the switch
No. | Indicator | nombre | Color Color Color Color | Estado de la situación | descripción |
---|---|---|---|---|---|
1 | SYS | Indicador de estado del sistema | - | fuera | El sistema no está funcionando. |
verde | Parpadeo rápido | El sistema está arrancando. | |||
verde | Firme sobre | Durante la fase de preparación de la puesta en marcha del sistema, el indicador SYS es de color verde constante, que dura un máximo de 30 segundos. | |||
verde | Parintermitente lento | El sistema está funcionando normalmente. | |||
Red | Firme sobre | A fault that affects services has occurred and it cannot be rectified automatically (critical alarm about hardware). | |||
2 | El MST | Indicador de pila | - | fuera | El interruptor no es el interruptor maestro en una pila. |
verde | parintermitente | El interruptor es el interruptor maestro en una pila o un interruptor independiente. | |||
3 | ID | Indicador de identificación | - | fuera | El indicador ID no se utiliza (estado por defecto). |
Azul azul | Firme sobre | El indicador identifica el interruptor a mantener. El indicador de identificación puede ser encendido o apagado remotamente para ayudar a los ingenieros de campo a encontrar el interruptor a mantener. | |||
4 | - | Indicador del puerto de servicio (dos indicadores para cada puerto) Nota:Cada puerto óptico tiene dos indicadores de un solo color. El de la izquierda es el indicador ACT (amarillo), yel de la derecha es el indicador LINK (verde). Las puntas de flecha muestran las posiciones de los puertos. Una punta de flecha hacia abajo indica un puerto en la parte inferior, y una punta de flecha hacia arriba indica un puerto en la parte superior. | Meanings of service port indicators vary in different modes. For details, see Table 4-12 and Table 4-13. | ||
5 | - | Indicador del puerto de servicio (un indicador para cada puerto) Nota:Each optical port has one single-color indicator. Arrowheads show the positions of ports. | |||
6 | L/A | El indicador del puerto | - | fuera | El puerto ETH no está conectado. |
verde | Firme sobre | El puerto ETH está conectado. | |||
verde | parintermitente | El puerto Eth está enviando o recibiendo datos. | |||
7 | USB | USB-based deployment indicator (en inglés) | - | fuera | No hay unidad flash USB instalada, o el indicador falla. |
verde | Firme sobre | El despliegue basado en USB tiene éxito. Si no hay un archivo de configuración de deployment, el deployment se realizará repetidamente. En este caso, el indicador también es verde constante. | |||
verde | parintermitente | El despliegue basado en USB está en progreso. | |||
Red | Firme sobre | Falla el despliegue basado en USB. |
Table 4-12 descripción of service port indicators in different modes (two indicators for each port)
Display Mode | Color | Estado de la situación | Description |
---|---|---|---|
Default mode (LINK indicator) | verde | fuera | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | Se ha establecido un enlace en el puerto. | |
Default mode (ACT indicator) | amarillo | fuera | El puerto no está enviando o recibiendo datos. |
amarillo | parintermitente | El puerto está enviando o recibiendo datos. | |
Speed mode (LINK indicator) Nota:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | fuera | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre |
| |
verde | parintermitente |
|
Table 4-13 Description of service port indicators in different modes (one indicator for each port)
Display Mode | Color | Estado de la situación | Description |
---|---|---|---|
Default mode | - | fuera | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | Se ha establecido un enlace en el puerto. | |
verde | parintermitente | El puerto está enviando o recibiendo datos. | |
Speed mode Nota:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | fuera | El puerto no está conectado o ha sido apagado. |
verde | Firme sobre | 40GE/100GE QSFP28 port: The port is operating at 40 Gbit/s. | |
verde | parintermitente |
|
The switch can use a single power module or two power modules for 1+1 power redundancy. Los módulos de alimentación de ca y DC enchupables se pueden utilizar juntos en el mismo interruptor.
The switch uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Table 4-14 Technical specifications of the S6730-H48X6C-V2
El artículo | especificación |
---|---|
Dimensiones sin embalaje (H x W x D) [mm(in.)] | Dimensiones básicas (excluyendo las partes que sobresalen del cuerpo): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. X 17.40 in. X 16.54 in.) Dimensiones máximas (la profundidad es la distancia desde los puertos en el panel frontal a las partes que sobresalen del panel trasero): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. X 17.40 in. X 17.56 in.) |
Dimensiones con embalaje (H x W x D) [mm(in.)] | 175.0 mm x 650.0 mm x 550.0 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Altura del chasis [U] | 1 |
Chassis material | Metal |
Peso sin embalaje [kg(lb)] | 5.84 kg (12.87 lb) |
Peso con embalaje [kg(lb)] | 9.2 kg (20.28 lb) |
Consumo típico de energía [W] | 165 W |
Disipación típica de calor [BTU/ hora] | 563 BTU/hour |
Consumo máximo de energía [W] | High temperature 45°C (113°F), 100% traffic, and dual power modules: 207 W High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 291 W |
Máxima disipación de calor [BTU/ hora] | High temperature 45°C (113°F), 100% traffic, and dual power modules: 706.30 High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 992.92 |
Consumo de energía estática [W] | 97 W |
MTBF [años] | 56.87 years |
MTTR [horas] | 2 horas |
disponibilidad | > 0.99999 |
Ruido A temperatura normal (potencia acústica) [dB(A)] | 65 dB(A) |
Ruido A temperatura normal (presión acústica) [dB(A)] | 52 dB(A) |
Número de ranuras de tarjetas | 0 |
Número de ranuras de corriente | 2 |
Número de módulos de ventil | 4 |
Fuente de alimentación redund | 1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Temperatura de funcionamiento a largo plazo [°C(°F)] | -5°C a +45°C (23°F a 113°F) a una altitud de 0-1800 m (0-5906 pies). |
Restricción de la tasa de variación de la temperatura de funcionamiento [− C(− F)] | Cuando la altitud es de 1800-5000 m (5906-16404 pies), la temperatura de operación más alta se reduce en 1°C (1,8 °F) cada vez que la altitud aumenta en 220 m (722 pies). Los dispositivos no pueden arrancar cuando la temperatura es inferior a 0°C (32°F). Cuando se utiliza el módulo óptico QSFP-100G-ER4, la temperatura de operación varía de -5°C a +40°C (23°F a 104°F). |
Temperatura de almacenamiento [°C(°F)] | -40°C a +70°C (-40°F a +158°F) |
Humedad relativa operativa a largo plazo [hr] | 5% a 95%, sin condensación |
Altitud operativa a largo plazo [m(ft.)] | 0-5000 m (0-16404 pies) |
Altitud de almacenamiento [m(ft.)] | 0-5000 m (0-16404 pies) |
Modo de alimentación | Fuente de alimentación enchufable |
Tensión nominal de entrada [V] |
|
Rango de tensión de entrada [V] |
|
Corriente máxima de entrada [A] | Las especificaciones actuales dependen de los módulos de alimentación enchufables en uso. Para más detalles, consulte las especificaciones relacionadas con el módulo de potencia. |
Memory | 4 GB |
Memoria Flash | Physical space: 2 GB |
Puerto de consola | RJ45 |
Gestión del puerto | RJ45 |
USB | apoyado |
RTC | Supported |
Entrada RPS | No soport |
Protección contra aumentos de tensión en los puertos de servicio [kV] | - |
Protección contra aumento de tensión de la fuente de alimentación [kV] |
|
Nivel de protección contra la entrada (resistente al polvo/al agua) | IP20 |
Tipos de ventiladores | Pluggable |
Modo de disipación del calor | Disipación de calor con ventilador, ajuste inteligente de la velocidad del ventilador |
Dirección del flujo de aire | Toma de aire desde el frente, aspiración de aire desde la parte trasera (de adelante hacia atrás) |
PoE | No soport |
certificación | Certificación EMC Certificación de seguridad Certificación de fabricación |