S5735-L8T4S-A-V2 Enterprise Network Switch Datasheet Overview

Apr, 10, 2026 Hi-network.com

S5735-L8T4S-A-V2

The S5735-L8T4S-A-V2 is a compact enterprise access switch designed for small campus networks, branch offices, and enterprise edge deployments. It provides high-performance Gigabit access connectivity combined with 10GE uplink capabilities, enabling flexible and scalable network expansion. The switch integrates Layer 2 switching, basic Layer 3 routing, security features, and intelligent QoS in a compact desktop form factor.


With silent fanless operation and energy-efficient hardware architecture, the S5735-L8T4S-A-V2 is ideal for deployment in offices, classrooms, retail stores, and other noise-sensitive environments. The switch supports flexible management options and simplified deployment, helping enterprises build reliable and easy-to-maintain access networks.


Key Features

The S5735-L8T4S-A-V2 offers enterprise-grade switching features designed for modern access-layer networking. It supports high-speed uplink connectivity, intelligent traffic management, and comprehensive security mechanisms to ensure reliable network performance.


Its compact design and fanless architecture allow flexible deployment in various enterprise scenarios. The switch delivers stable performance for unified communications, wireless access, and IP surveillance deployments.


▪ Compact desktop deployment design
▪ Fanless silent operation architecture
▪ 8 x Gigabit Ethernet access ports
▪ 4 x 10GE SFP+ uplink interfaces
▪ Layer 2 and Layer 3 switching support
▪ IPv4 and IPv6 dual stack capability
▪ Advanced QoS traffic scheduling
▪ Comprehensive security protection
▪ Energy-efficient hardware design
▪ Flexible management and deployment

Key Especificaciones técnicas

The S5735-L8T4S-A-V2 provides reliable switching performance and enterprise-grade hardware specifications. The device supports wire-speed forwarding and stable operation for branch and campus access networks.


Its compact footprint does not compromise performance. The switch integrates high-speed uplinks and intelligent traffic processing to ensure efficient bandwidth utilization.


▪ Los puertos:  8 x Puerto 10/100/1000BASE-Ts, 4 x 10GE SFP+ uplink ports
▪ Switching Capacity:  High-performance switching architecture
▪ Forwarding Performance:  Wire-speed packet forwarding
▪ MAC Address Table:  Large MAC address capacity
▪ VLAN Support:  Extensive VLAN ID range support
▪ Routing Capability:  Static routing and inter-VLAN routing
▪ Management Interfaces:  Console and Ethernet management
▪ Cooling Mode:  Fanless passive cooling
▪ Power Consumption:  Low power design
▪ Deployment:  Desktop and wall mounting
▪ Operating Temperature:  Enterprise operating range

Hardware Architecture

Compact Enterprise Hardware Design

The S5735-L8T4S-A-V2 adopts a compact hardware design optimized for enterprise access deployment. The switch integrates high-performance switching chips to provide reliable forwarding performance across all ports. This architecture ensures stable operation for bandwidth-intensive applications.


The compact enclosure allows flexible installation in limited spaces. The device can be deployed on desktops, in cabinets, or mounted on walls, making it suitable for branch offices and enterprise edge environments.


Fanless Silent Operation

The fanless cooling design eliminates mechanical components, reducing hardware failure risks. This design improves reliability and minimizes maintenance requirements over long-term operation.


Silent operation allows deployment in noise-sensitive environments such as classrooms, offices, and retail counters. Passive cooling also reduces dust intake and increases device lifespan.


puerto Configuration and Connectivity

Gigabit Access Ports

The switch provides eight Gigabit Ethernet access ports for connecting endpoint devices. These ports support PCs, wireless access points, IP phones, and surveillance cameras. Gigabit connectivity ensures sufficient bandwidth for modern enterprise applications.


Auto-negotiation and auto MDI/MDIX features simplify deployment. Administrators can connect devices directly without manual configuration, enabling fast and efficient installation.


10GE Uplink Interfaces

The S5735-L8T4S-A-V2 includes four 10GE SFP+ uplink ports for high-speed aggregation connectivity. These uplinks provide sufficient bandwidth for upstream traffic and prevent bottlenecks.


Fiber uplinks support long-distance connectivity across buildings or floors. This makes the switch suitable for campus networks and enterprise backbone connections.


Layer 2 Switching Features

VLAN and Network Segmentation

The switch supports VLAN-based network segmentation to isolate departments and services. VLAN configuration reduces broadcast traffic and improves network security.


Administrators can configure port-based VLANs, tagged VLANs, and trunk links. These features allow flexible network design and simplified management.


Link Aggregation and Loop Protection

Link aggregation combines multiple physical links into a single logical connection. This increases bandwidth and provides redundancy for critical network links.

Spanning tree protocols prevent loops and maintain stable network topology. These features ensure reliable operation even when network changes occur.


Layer 3 Routing Capabilities

Static Routing Support

The S5735-L8T4S-A-V2 supports static routing for inter-network communication. This reduces reliance on external routers and simplifies network architecture.

Routing within the switch improves performance and reduces latency. Internal traffic can be forwarded efficiently between subnets.


Inter-VLAN Routing

Inter-VLAN routing allows communication between VLANs directly on the switch. This eliminates the need for separate routing devices.


This feature improves network efficiency and simplifies design. It is especially useful for campus and branch deployments.


Calidad de servicio (QoS)

Traffic Prioritization

The switch supports QoS classification based on multiple parameters. Critical applications such as voice and video can receive higher priority.


Priority queues ensure delay-sensitive traffic is forwarded first. This improves application performance and user experience.


Bandwidth Management

The S5735-L8T4S-A-V2 supports traffic shaping and bandwidth control. Administrators can allocate bandwidth to different services.


These capabilities prevent congestion and ensure fair usage. Network performance remains stable during peak traffic.


Elementos de seguridad

Access Control Protection

The switch supports port-based access control and MAC authentication. These features restrict unauthorized device access.


Access control policies enhance network security. Administrators can define user permissions at the access layer.


Network Attack Prevention

Security mechanisms such as DHCP snooping and storm control are supported. These features protect against common attacks.


ACL filtering further improves security. The switch ensures safe and stable network operation.


Soporte para IPv6

Dual Stack Networking

The S5735-L8T4S-A-V2 supports IPv4 and IPv6 dual stack operation. This enables gradual IPv6 migration.


Dual stack ensures compatibility with modern networks. Organizations can transition smoothly.


IPv6 Routing and Security

The switch supports IPv6 routing and filtering. These capabilities enable IPv6 network deployment.


IPv6 QoS and ACL features ensure performance and security. The switch is ready for next-generation networks.


Management and Deployment

Flexible Management Options

The switch supports CLI, web interface, and centralized management. Administrators can choose preferred configuration methods.


Remote management simplifies maintenance. Monitoring and troubleshooting can be performed efficiently.


Easy Deployment

The S5735-L8T4S-A-V2 supports plug-and-play deployment. Default configuration enables quick installation.


Configuration backup and restore reduce downtime. Deployment efficiency is improved.


Energy Efficiency

Low Power Consumption

The switch uses energy-efficient components to reduce power usage. Fanless architecture lowers energy consumption.


Low power operation reduces operational costs. The device supports continuous deployment.


Environment Friendly Design

The compact hardware reduces material usage. Passive cooling eliminates additional energy requirements.


These features support environmentally friendly networking. Enterprises benefit from efficient operation.


Use Case Scenarios

Campus Access Deployment

The S5735-L8T4S-A-V2 is ideal for campus access networks. It connects user devices and uplinks to aggregation switches.


High-speed uplinks ensure sufficient bandwidth. The switch supports scalable campus deployment.


Branch Office Networking

The switch provides reliable connectivity for branch offices. It supports wired devices and wireless access points.


Silent operation and compact size enable flexible installation. Branch networks benefit from simplified management.


conclusión

The S5735-L8T4S-A-V2 is a compact enterprise access switch designed for modern network deployments. It provides Gigabit access connectivity and high-speed 10GE uplinks for scalable architecture.


With Layer 2 and Layer 3 capabilities, QoS features, security protection, and flexible management, the switch delivers reliable performance for campus and branch networks. The S5735-L8T4S-A-V2 is an ideal solution for enterprise access layer deployments.


Huawei S5735 Series Switches

Huawei All Series Switches New and Used

For Huawei product list and quote, please visit: https://www.hi-network.com/categories/huawei or contact us at www.hi-network.com  (Email: info@hi-network.com (en inglés))


S5735-L8T4S-A-V2 (98011977)

Vista general

Table 4-233 Basic information about the S5735-L8T4S-A-V2
El artículodetalles
descripciónS5735-L8T4S-A-V2 (8*10/100/1000BASE-T ports, 4*GE SFP ports, AC power)
Número de pieza98011977
modeloS5735-L8T4S-A-V2
Primera versión compatibleV600R022C01

Componentes componentes

Figure 4-72 S5735-L8T4S-A-V2 appearance

1

Botón de un modo

2

ochoRe88pl99ace110/100/1000BASE-T ports

3

Cuatro puertos 1000BASE-X

4

Un puerto de consola

5

Un botón de un PNP

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

6

Tornillo de tierra

Nota:
It is used with a ground cable.

7

Toma de corriente alter

Nota:

It is used with an AC power cable.

8

Jack para la correa de cierre del cable de alimentación alterna

Nota:
The AC power cable locking strap is not delivered with the switch.

Ports

Table 4-234 Ports on the S5735-L8T4S-A-V2
PortTipo de conectordescripciónAvailable Components
10/100/1000BASE-T portRJ45A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s.

Ethernet cable

1000BASE-X PortSFPA 1000BASE-X port can send and receive data at 1000 Mbit/s.
  • GE eSFP optical modules

  • GE-CWDM eSFP optical modules

  • GE-DWDM eSFP optical modules

  • GE SFP copper module

  • 10GE SFP+ optical modules (only used for stack connection)

  • 10GE-CWDM SFP+ optical modules (only used for stack connection)

  • 10GE-DWDM SFP+ optical modules (only used for stack connection)

  • 1 m and 3 m SFP+ high-speed copper cables (only used for stack connection)

  • 10 m SFP+ AOC cables (only used for stack connection)

  • 0.5 m and 1.5 m SFP+ dedicated stack cables (only used for stack connection; zero-configuration stacking supported from V600R023C00)

  • 3 m SFP+ dedicated stack cable (V600R025C10 and later versions, only for zero-configuration stacking)

Puerto de consolaRJ45The console port is connected to a console for on-site configuration.

Console cable

Indicators and Buttons

The S5735-L8T4S-A-V2 has similar indicators to those on the S5735-L8P2T4X-A-V2 except that the S5735-L8T4S-A-V2 does not have a PoE mode indicator. For details, see the S5735-L8P2T4X-A-V2.

Power Supply System

The switch has a built-in AC power module and does not support pluggable power modules.

Heat Dissipation System

The switch has a built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.

When working properly at a normal temperature, the device meets the desktop-class noise requirements. However, the fan speed may be high and the noise may be loud during device startup.

This figure only shows the airflow direction and does not depict the actual device.

Technical especificacións

Table 4-235 Technical specifications of the S5735-L8T4S-A-V2
El artículoSpecification
Dimensiones sin embalaje (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 250.0 mm x 180.0 mm (1.72 in. x 9.84 in. x 7.09 in.)

Dimensiones máximas (la profundidad es la distancia de los puertos en el panel frontal a las partes que sobresalen del panel trasero): 43,6 mm x 250,0 mm x 187,0 mm (1,72 in. X 9.84 in. X 7.36 in.)

Dimensiones con embalaje (H x W x D) [mm(in.)]90,0 mm x 370,0 mm x 380,0 mm (3.54 in. X 14.57 in. X 14.96 in.)
Altura del chasis [U]1
Chassis materialMetal
Peso sin embalaje [kg(lb)]1.41 kg (3.11 lb)
Peso con embalaje [kg(lb)]2.22 kg (4.89 lb)
Consumo típico de energía [W]15.95 W
Disipación típica de calor [BTU/ hora]54.42 BTU/hour
Consumo máximo de energía [W]21.52 W
Máxima disipación de calor [BTU/ hora]73.43 BTU/hour
Consumo de energía estática [W]10.52 W
MTBF [años]75.32 years
disponibilidad> 0.99999
Ruido A temperatura normal (potencia acústica) [dB(A)]44.5 dB(A)
Ruido A temperatura normal (presión acústica) [dB(A)]32.5 dB(A)
Número de ranuras de tarjetas0
Número de ranuras de corriente0
Número de módulos de ventil1
Fuente de alimentación redundNo soport
Temperatura de funcionamiento a largo plazo [°C(°F)]-5°C a +50°C (23°F a 122°F) a una altitud de 0-1800 m (0-5905.44 pies).
Restricción de la tasa de variación de la temperatura de funcionamiento [− C(− F)]

Cuando la altitud es de 1800-5000 m (5906-16404 pies), la temperatura de operación más alta se reduce en 1°C (1,8 °F) cada vez que la altitud aumenta en 220 m (722 pies).

Los dispositivos no pueden arrancar cuando la temperatura es inferior a 0°C (32°F).

Temperatura de almacenamiento [°C(°F)]-40 °C a +70°C (-40 °F a +158°F)
Humedad relativa operativa a largo plazo [hr]5% de hr a 95% de hr, sin condensación
Altitud operativa a largo plazo [m(ft.)]0-5000 m (0-16404 pies)
Altitud de almacenamiento [m(ft.)]0-5000 m (0-16404 pies)
Modo de alimentaciónDe ca
Tensión nominal de entrada [V]Entrada AC: 100-240 V AC; 50/60 Hz
Rango de tensión de entrada [V]AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz
Corriente máxima de entrada [A]0,8 A
memoria2 GB
Memoria FlashEspacio físico: 1 GB
Puerto de consolaRJ45
Gestión del puertoNo soport
USBNo soport
RTCNo soport
Entrada RPSNo soport
Protección contra aumentos de tensión en los puertos de servicio [kV]Modo común: − 7 kV
Protección contra aumento de tensión de la fuente de alimentación [kV]Modo diferencial: − 6 kV; Modo común: − 6 kV
Nivel de protección contra la entrada (resistente al polvo/al agua)IP20
Tipos de ventiladoresIncorporado en el
Modo de disipación del calorRefrigeración por aire para disipación de calor, ajuste inteligente de la velocidad del ventilador
Dirección del flujo de aireToma de aire por la izquierda y por delante, aspiración de aire por la derecha
PoENo soport
certificación

Certificación EMC

Certificación de seguridad

Certificación de fabricación


tag-icon Etiquetas calientes: Huawei Switches hot products

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.